image 2 image 4
Skip Navigation Links
 Home 
 Congress Structure 
 Important Dates 
 Venue 
 Registration 
 Pre Registered 
 Hotel Info 
 Abstracts 
 Scientific Program 
 Social Program 
 Exhibition 
 Contact Us 
       XXV Annual Congress of the Iranian Society of Ophthalmology        بـیــست و پنجمین کنــگــره سـالیـانه انـجـمـن چـشـم پـزشـکی ایـــران
مقاله Abstract


Title: The visual and refractive outcomes and aberrometric change of aspheric wavefront-guided vs aspheric laser-assisted subepithelial keratectomy with TENEOTM 317 P for myopia correction (prospective 6.0 m
Author(s): Seyed javad Hashemian, Mohammad Ebrahim Jafari
Presentation Type: Poster
Subject: Cornea and Anterior Segment
Others:
Presenting Author:
Name: Seyed javad Hashemian
Affiliation :(optional) Eye Research Center, Rassoul Akram Hospital, Tehran University of Medical Sciences, Tehran, IRAN
E mail: sj_hashemian@yahoo.com
Phone: 22583455
Mobile: 09121142168
Purpose:

To comparison the visual and refractive outcomes and aberrometric changes of aspheric-wave front-guided versus aspheric LASEK with TECHNOLAS TENEO 317-P excimer-Laser for myopia correction.

Methods:

Sixty-six eyes of 34 patients with myopia treated by TENEO 317-P excimer-Laser. 45 eyes treated with aspheric-wavefront-guided(AWG) and 21 eyes with aspheric LASEK(Aspheric group). Uncorrected and Distant corrected visual-acuity (UCVA & DCVA), aberrometric changes and complications were evaluated 1-week, 2 and 6-months post operation

Results:

The mean spherical equalent was -3.69±1.42 diopter(D) in AWG and -3.57±1.29 D in AG that improved to .06±.22 and .14±.25D 6 months post operation respectively. At 6 months LogMar UCVA and CDVA in both groups was 0.000 in all of patients. The higher order aberrations (HOAs) at 6mm pupil were .350μ in AWG and .270μ in AG that increased to .464μ and .431μ (30% versus 45%) respectively (P=0.00). Vertical coma and spherical aberration increased significantly (P=0.001). No eye lost lines of BSCVA at six months. The safety and efficacy index in both groups was 1 without any complications

Conclusion:

Both aspheric wave front-guided and aspheric ablation profile of TENEO 317P is safe and effective with a little change in HOAs in myopic patients treated with LASEK

Attachment:





Skip Navigation Links
        صفحه اصلی
        ساختار کنگره
        تاریخ های مهم
        مکان برگزاری
        ثبت نام
        ثبت نام شدگان
        اطلاعات هتل - رزرو
        مقالات
        برنامه کنگره
        جشنواره فیلم و عکس
        نمایشگاه
        تماس با ما
        جستجوی سخنران
 
Last News

  - بـیــست و پنجمین کنــگــره سـالیـانه انـجـمـن چـشـم پـزشـکی ایـــران