image 2 image 4
Skip Navigation Links
 Home 
 Congress Structure 
 Important Dates 
 Venue 
 Registration 
 Pre Registered 
 Hotel Info 
 Abstracts 
 Scientific Program 
 Social Program 
 Exhibition 
 Contact Us 
       XXV Annual Congress of the Iranian Society of Ophthalmology        بـیــست و پنجمین کنــگــره سـالیـانه انـجـمـن چـشـم پـزشـکی ایـــران
مقاله Abstract


Title: Evaluation of Corvis ST and Ocular Response Analyzer indices changes after laser refractive surgery
Author(s): Mohammadreza Sedaghat, Arash Omidtabrizi, Alireza Vahedi, Masoud Shafiee
Presentation Type: Oral
Subject: Cornea and Anterior Segment
Others:
Presenting Author:
Name: Arash Omidtabrizi
Affiliation :(optional) Ophthalmologist, Eye research center, Mashhad University of Medical Sciences, Mashhad, Iran
E mail: arash_omid2001@yahoo.com
Phone: 05138933130
Mobile: 09395085448
Purpose:

To investigate corneal biomechanic changes by evaluating Corvis ST and Ocular Response Analyzer (ORA) parameters after LVC.

Methods:

Eighty six eyes were studied in 2 groups; group 1: individuals undergoing PRK (144 eyes), and group 2: individuals undergoing femtosecond assisted LASIK (24 eyes). ORA and Corvis ST measurements were performed by an experienced technician before and 4 months after LVC.

Results:

Multivariate analysis showed that corneal thickness and mean keratometric power have a confounding effect on Corvis ST and ORA parameters (P=0.00). First applanation time, second applanation time, time of highest concavity and peak distance showed a significant change independently to the type of surgery; although the change was more remarkable in PRK group. Corneal Hysteresis (CH) and Corneal Resistance Factor (CRF) in ORA decreased significantly (P=0.38 and P=0.017, respectively). Intraocular pressure (IOP) didn’t change significantly in Corvis ST and ORA (P=0.452 and P=0.407, respectively).

Conclusion:

Corneal deformation in response to air puff occurs faster and reverses slower after LVC. ORA and to some extent Corvis measurements suggest reduction of corneal resistance after LVC. Although not significant, Lasik eyes show less change in Corvis and ORA parameters 4 months post-operatively. ORA and Corvis IOP measurement are reliable after LVC.

Attachment:





Skip Navigation Links
        صفحه اصلی
        ساختار کنگره
        تاریخ های مهم
        مکان برگزاری
        ثبت نام
        ثبت نام شدگان
        اطلاعات هتل - رزرو
        مقالات
        برنامه کنگره
        جشنواره فیلم و عکس
        نمایشگاه
        تماس با ما
        جستجوی سخنران
 
Last News

  - بـیــست و پنجمین کنــگــره سـالیـانه انـجـمـن چـشـم پـزشـکی ایـــران